Product overview
What it is and where it fits.
The AR209 protects air compressors and similar intake equipment from dust that would wear internal parts and contaminate compressed air. Two versions are listed: a deep glass-fibre filter for high efficiency at small particle sizes, and a shallow synthetic filter for coarser duty.
The deep version (24 × 24 × 11½ in) uses water-resistant micro-glass fibre, a galvanised frame, epoxy-sealed media ends and a HEPA-grade gasket, with a listed dust capacity of 585 g and pleat strength above 34 in w.g. The shallow version (24 × 24 × 1½ in) uses synthetic media with PVC end seals and protective mesh, rated at least 98% at 10 µm.
- Filter type
- Compressor / intake filter
- Deep version
- 24 × 24 × 11½ in, glass fibre, epoxy-sealed, galvanised frame
- Shallow version
- 24 × 24 × 1½ in, synthetic, PVC seals, protective mesh
- Shallow efficiency
- ≥ 98% at 10 µm
- Dust capacity (deep)
- 585 g at 4 in w.g.
- Pleat strength (deep)
- > 34 in w.g.
Typical applications
- Air compressor intakes
- Industrial equipment and turbine-style air intakes
- Dusty plant rooms
Construction & performance
Deep glass-fiber version
Nominal size: 24 × 24 × 11½ in. Water-resistant micro-glass fiber media; galvanized steel frame; epoxy-sealed media ends and a HEPA-grade gasket. Efficiency 99.97% at 2 μm; 94% dust-spot efficiency.
Operating data
Dust-holding capacity: 585 g at 4 in w.g. Pleat strength: above 34 in w.g.; each filter is individually tested.
Shallow synthetic version
Nominal size: 24 × 24 × 1½ in. Synthetic fiber media with a galvanized steel frame, PVC end seals and protective mesh. Efficiency ≥ 98% at 10 μm.
Selection guide
How to choose.
Choose by the particle size you must stop
The deep glass-fibre version targets fine particles around 2 µm; the shallow synthetic version targets coarser dust around 10 µm.
Technical data
Specifications & dimensions.
Rated airflow in m³/h, pressure drop in Pa, actual dimensions in mm, nominal sizes in inches. Swipe tables sideways on small screens.
| Particle size (µm) | Efficiency |
|---|---|
| 10 | 98% |
| 2 | 99.97% |
| Test standard: ASHRAE 52.1-1992 / EN 779 | |
Catalogue values at rated airflow. Test data for your exact configuration is available on request.
Original Yiding catalogue (Chinese) ↗FAQ
Common questions.
Why filter compressor intake air?+